Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Verifiering av mikrobuljongspädning med Sensititre™-paneler för MIC-bestämning av grampositiva kocker
Jönköping University, School of Health and Welfare, HHJ, Dep. of Natural Science and Biomedicine.
Jönköping University, School of Health and Welfare, HHJ, Dep. of Natural Science and Biomedicine.
2021 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Verification of broth microdilution with Sensititre™ panels for MIC determination of gram-positive cocci (English)
Abstract [sv]

Resistensbestämningar som genererar ett kvantitativt MIC-värde är värdefullt för att kunna välja adekvat antibiotikabehandling. Referensmetoden för MIC-bestämning är mikrobuljongspädning där kommersiella antibiotikapaneler underlättar handhavandet av metoden på kliniska laboratorier. Syftet med studien var att verifiera mikrobuljongspädning med Sensititre™-panelerna SEMSE7 och SEMST7 avsedda för grampositiva kocker, genom att jämföra erhållet resultat med tidigare uppmätta referensvärden av MIC samt SIR-kategorier. Mikrobuljongspädning utfördes med SEMSE7-panel och MH-buljong för Staphylococcus spp. (n=21) och Enterococcus spp. (n=13) samt med SEMST7-panel och MH-F buljong för Streptococcus pneumoniae (n=20). Avläsning av MIC utfördes samt tolkades enligt SIR-systemet. Resultaten jämfördes mot kända referensvärden tidigare uppmätta med mikrobuljongspädning. Isolat analyserade med SEMSE7-panel och SEMST7-panel erhöll en överensstämmelse av MIC på 88,2% respektive 96,7%. Motsvarande kategorisk överensstämmelse av SIR var 92,5% respektive 92,6%. Resultatet visar att Sensititre™-panelen SEMST7 är godkänd i verifieringen av mikrobuljongspädning med god överensstämmelse med referensvärden av MIC samt SIR-kategorier. Vidare bedöms att fortsatt verifiering krävs av SEMSE7-panelen eftersom ej tillfredställande överenstämmelse med referensvärden av MIC erhölls, trots god överenstämmelse av SIR-kategorier. Studien visar att SEMST7-panelen kan implementeras för Streptococcus pneumoniae i den kliniska verksamheten på mikrobiologilaboratoriet, Jönköping.

Abstract [en]

Antimicrobial susceptibility testing methods generating a quantitative MIC are valuable for choosing adequate antibiotic treatment. Broth microdilution is the reference method for MIC determination and commercial panels with antibiotics facilitate the procedure in clinical laboratories. The aim of the study was to verify broth microdilution with the Sensititre™ panels SEMSE7 and SEMST7 designed for gram-positive cocci, by comparing results with previously measured reference values of MIC and SIR. Broth microdilution was performed using the SEMSE7 panel with MH broth for Staphylococcus spp. (n=21) and Enterococcus spp. (n=13), and using the SEMST7 panel with MH-F broth for Streptococcus pneumoniae (n=20). Reading MIC endpoints was performed and interpreted according to SIR system. Isolates analysed with the SEMSE7 and SEMST7 panel obtained essential agreement of 88,2% and 96,7%, and categorical agreement of 92,5% and 92,6% respectively. In conclusion, the Sensititre™ panel SEMST7 is approved in the verification of broth microdilution with satisfactory essential agreement and categorical agreement. Furthermore, it is considered that further verification is required for the SEMSE7 panel as unsatisfactory essential agreement was obtained, despite satisfactory categorical agreement. The study shows that the SEMST7 panel can be implemented for Streptococcus pneumoniae in the clinical practice at the microbiology laboratory, Jönköping. 

Place, publisher, year, edition, pages
2021.
Keywords [en]
antibiotic resistance, antimicrobial susceptibility testing, broth microdilution, Sensititre™, SEMSE7, SEMST7
Keywords [sv]
antibiotikaresistens, resistensbestämning, mikrobuljongspädning, Sensititre™, SEMSE7, SEMST7
National Category
Biomedical Laboratory Science/Technology Microbiology
Identifiers
URN: urn:nbn:se:hj:diva-52931ISRN: JU-HHJ-BLA-1-20210109OAI: oai:DiVA.org:hj-52931DiVA, id: diva2:1562424
External cooperation
Region Jönköpings län
Subject / course
HHJ, Biomedical Laboratory Science
Available from: 2021-06-14 Created: 2021-06-08 Last updated: 2025-10-13Bibliographically approved

Open Access in DiVA

fulltext(3413 kB)631 downloads
File information
File name FULLTEXT01.pdfFile size 3413 kBChecksum SHA-512
d7d088e670bade1de347513f86ecb3aeeca37acf68e4de39c820b8fa95e900e4e5e1957c834d9a3b13697109fe0ac6203f8620fa6b2955be12138ab835683439
Type fulltextMimetype application/pdf

By organisation
HHJ, Dep. of Natural Science and Biomedicine
Biomedical Laboratory Science/TechnologyMicrobiology

Search outside of DiVA

GoogleGoogle Scholar
Total: 631 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 979 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf